HIOKI 3030-10 HiTester - Analog Multimeter 
  • Drop proof design withstands dropping onto a concrete floor from a height of 1 meter
  • LED check, Battery check, or Temperature measurement support (with optional probes)
AUD $ 100.00 ex GST

Product Details

HIOKI 3030-10 HiTester

Basic tester with improved safety features (20kO/V)

Drop proof design withstands dropping onto a concrete floor from a height of 1 meter. LED check, Battery check, or Temperature measurement support (with optional probes).

DC Voltage range : 0.3 V (16.7 k-ohm/V), 3/12/30/120/300/600 V (20 k-ohm/V)
Accuracy: ±2.5 % f.s. Max. rated voltage: 600 V

AC Voltage range : 12 V (9 k-ohm/V) Accuracy: ±4 % f.s.
30/120/300/600 V (9 k-ohm/V) Accuracy: ±2.5 % f.s.
Average rectifier effective value Max. rated voltage: 600 V

DC Current range : 60 µA/30 m/300 mA (300 mV internal voltage drop)
Accuracy: ±3 % f.s.

Resistance range : 0 to 3 k-ohm (center scale 30 ohm), R × 1, R × 10, R × 100, R × 1 k
Accuracy: ±3 % of scale length

Battery check : 0.9 to 1.8 V, load resistance 10 ohm, Accuracy: ±6 % f.s.

Temperature scale : -20 to 150°C, Use with R ×100 range (Thermister Temperature Probe 9021-01 is necessary, sold separately), Accuracy: ±3 % of scale length

Power supply : For resistance measurement range, R6P (AA) × 2 batteries

Dimensions, mass : 95 mm(3.74 in)W × 141 mm(5.55 in)H × 39 mm(1.54 in)D, 280 g (9.9 oz)

Supplied accessories : TEST LEAD×1, Spare fuse×1, Manganese batteries (R6P)×2, Instruction Manual×1, CARRYING CASE 9390×1

MEGGER Dual-Voltage, Heavy-Duty Impulse Generators • Dual-Voltage Model • Heavy-Duty Model Impulse Generators are designed to locate faults in power cable by the high voltage impulse ...
APLAB Model HICOMP HT Cable Fault Locating System HICOMP 16 compact module comprises of minimum configuration of high voltage cable fault locating instruments, mounted on a robust trolley...
MEGGER MPP1000 Pinpointer Cable fault distance and direction via single or dual detection configuration. Rugged, compact weather resistant housing. Ambient noise reduction headphones. Eas...
MEGGER L1071 Portable Locators Multiple frequencies, Transmits AF or RF signals or both simultaneously, Peak and null detection, Passive 60 Hz, Measures current flow in buried conductors ...
HIGH VOLTAGE CDS-3616U(F) Network System Thumper Controlled Energy Capacitor Discharge Systems Surge Generators – Thumpers HVI produces some of the most powerful and full featured fault l...