Free Call Australia : 1 800 834 991

Related Products

Mirus Combined Neutral Current Eliminator (CNCE)

MIRUS Combined Neutral Current Eliminator (CNCE) 
  • Diverts the flow of harmonic currents away from neutral and upstream transformer
  • A patented phase shifting autotransformer with a low zero sequence impedance at its output
  • Integrated ammeter measures neutral current removed

Product Details

MIRUS Combined Neutral Current Eliminator (CNCE)

A patented phase shifting autotransformer with a low zero sequence impedance at its output. When connected in series on a 3-phase, 4-wire service to non-linear loads, it provides an alternate path for the triplen harmonics. The CNCE™ also phase shifts 5th and 7th current harmonics by 180º so that they cancel with 5th and 7th harmonics from other loads on the distribution system. Optional FAI feature allows for removal of triplens from the CNCE™ input side as well as secondary.

Reduces neutral current, and neutral-to-ground voltage, as well as both current and voltage harmonic distortion at 3rd, 5th, 7th, & 9th harmonics.

Features

• Diverts the flow of harmonic currents away from neutral and upstream transformer
• Reduces high neutral current and neutral-to-ground voltage
• Eliminates the need for doable ampacity neutrals upstream
• Reduces losses and lowers operating temperature in upstream distribution transformer
• Substantially reduces primary winding circulating currents in distribution transformers
• Reduces current distortion at UPS, generator or Utility service
• Saves energy by reducing harmonic losses
• Prevents voltage flat-topping caused by non-linear loads
• Lowers voltage distortion to prevent premature equipment failure
• Restores ride-through capability of computer equipment
• Improves Power Factor
• Integrated ammeter measures neutral current removed
• Field adjustable impedance option offers improved application flexibility
• Helps meet IEEE Standard 519 harmonic limits

OMICRON CP TD1 Capacitance/Dissipation Factor Testing Device (Tan Delta) Combined with the CPC 100, the CP TD1 measures the capacitance and dissipation factor (power factor) with laborato...
OMICRON CPC 100 Universal Testing Device Electrical tests on transformers, current transformers, voltage transformers, grounding systems, lines and cables, and circuit breakers can be per...
OMICRON CPC 100 Universal Testing Device Electrical tests on transformers, current transformers, voltage transformers, grounding systems, lines and cables, and circuit breakers can be per...
MEGGER DELTA 2000 10-kV Automated Insulation Power Factor Test Set Extremely easy-to-use with no extensive hardware or software setup. Designed to work in high interference switchyards of...
MEGGER DELTA4110 Series 12 kV Insulation Diagnostic System Automatic and manual operation. Accurate and repeatable measurement results with high noise suppression. Lightweight, rugged two...