EuroSMC ETP-4 Short Circuit Impedance Measurement Unit

The measurement equipment ETP-4 is a unit that automatically performs the following measurements in all type of power, distribution, or instruments transformers:

- Short circuit Impedance measurement.
- Short circuit current at the test voltage.
- Short circuit power loss.

The unit performs the test in a fully automatic way. The test voltage is generated through a motor driven "variac". This assures the repeatability of the successive tests in terms of the voltage application mode and avoids undesired risks due to sudden transients.

APPLICATIONS

From the information supplied by this test unit it is possible to have an idea about the physical integrity of the transformer under test. The typical problems that are easily detected with this unit are the following:

- Physical displacement of the transformer windings, due to electromagnetic efforts.
- Problems in the iron core.
- Transport damages.
- Fixation elements which may be broken.

The program obtains from the measured values the components of the impedance triangle in short circuit. From this information, and its evolution in time it is possible to determine which part of the transformer is being deteriorated.
The test also confirms any incipient problem, which may have been detected with other test equipment that make up the ETP system.
The following types of voltage transformers can be tested with the ETP-4, despite the size and power:

- Power Transformers (single or three phase).
- Distribution Transformers (single or three phase).
- Power Autotranformers (single or three phase)
Instrument Voltage Transformers.

CHARACTERISTICS

- The software program guides the correct connection of the test cables on the primary winding and the short circuits that must be done in the secondary (or tertiary) side, according with the specific connection group the transformer under test has.
- The software program recommends the tap changer positions that should be tested according with the maximum regulation % and the nominal tap.

Displays and records the current and voltage waveform. This improves the diagnostic capability for further analysis.

HIOKI 3290 Clamp-On AC/DC HiTester All the Functions You Need for Measurement at DC or 1Hz and Up Choice of three sensors (Example combinations) 3290/3290-10 +9691 : Measure up to 100A ...
HIOKI 3280-10 Clamp-On HiTester Easy clamping in narrow locations with 16 mm slim body Model 3280-10: Display about nearest basic wave element of harmonic wave by average rectified. Model...
HIOKI 3285-20 Clamp-On AC/DC HiTester AC/DC current measuring up to 2000 A Analog output for current measuring level, current measuring waveform, or frequency measuring level. The peak ho...
FLUKE 355 True-rms 2000 A Clamp Meters Versatile and rugged tools for applications with high currents Confidently take reliable readings with the True-rms, Fluke 355 and 353 digital cl...
HIOKI 3285 Clamp-On AC/DC HiTester AC/DC current measuring up to 2000 A Analog output for current measuring level, current measuring waveform, or frequency measuring level. The peak hold ...